Valid in Indonesia only

Respironics V60 Plus Ventilator

Respironics V60

Non-invasive ventilator

The Philips Respironics V60 ventilator is our gold standard hospital dedicated noninvasive ventilator. With advanced breath delivery technology and algorithms designed to maximize performance in a leak prone environment, V60 adapts to your patients’ ventilation needs.
 

Specifications

General
Oxygen inlet pressure range
  • 276 to 600 kPa (40 to 87 psig)
Weight with optional battery
  • 10.9 kg (24 lb)
Weight without optional battery
  • 10.0 kg (22 lb)
Dimensions
  • 33.7 cm H x 39.4 cm W x 42.9 cm D (13.3"H x 15.5" W x 16.5" D)
Patient types
Suitability
  • Pediatric (≥ 20 kg) and Adult
Electrical - IntelliBridge EC40/80
AC voltage
  • 100 to 240 VAC
AC frequency
  • 50 to 60 Hz
AC power
  • 300 V·A
Battery operating time
  • 6 hours in normal conditions
Settings
IPAP
  • 4 to 40 cm H?O
C-Flex
  • Off, 1 to 3
CPAP
  • 4 to 25 cm H?O
Max P (PPV maximum pressure limit)
  • 5 to 40 cm H?O
EPAP
  • 4 to 25 cm H?O
Max P (AVAPS maximum IPAP)
  • 6 to 40 cm H?O
Inspiratory time
  • 0.30 to 3.00 sec
Min P (AVAPS minimum IPAP)
  • 5 to 30 cm H?O
Oxygen percentage
  • 21 to 100 %
Ramp time
  • Off, 5 to 45 min
Respiratory rate
  • 4 to 60 beats per minute
Rise time
  • 1 to 5
Triggering and cycling
  • Auto-adaptive (Auto-Trak) or Auto-Trak Plus (optional). Trigger: normal, +1 to +7. Cycle: -2, -1, normal, +1 to +6
AVAPS target tidal volume
  • 200 to 2000 ml BTPS
Max E
  • 0 to 100 cm H?O/l
Max R
  • 0 to 50 cm H?Ol/s
PPV%
  • 0 to 100 %
Max V (PPV maximum volume limit)
  • 200 to 3500 ml
Patient Data
Breath phase/trigger indicator
  • Spontaneous, Timed, Exhale
PIP
  • 0 to 50 cm H?O
Patient/total leak
  • 0 to 200 l/min BTPS
Patient Trigger
  • 0 to 100 %
Respiratory Rate
  • 0 to 90 beats per minute
Ti/Ttot
  • 0 to 91 %
Minute volume
  • 0 to 99.0 l/min BTPS
Tidal volume
  • 0 to 3000 ml BTPS
Waveform window
Pressure waveform
  • 0 - 50 cm H?O
Flow waveform
  • 240-2401 /min BTPS
Volume waveform
  • 0 - 3,500 ml BTPS
Alarm adjustable range
Lo Rate (low respiratory rate alarm)
  • 1 - 89 beats per minute
Hi Rate (hi respiratory rate alarm)
  • 5 - 90 beats per minute
Hi Vr (high tidal volume alarm)
  • 200 - 3,500 ml
Lo Vr (low tidal volume alarm)
  • OFF - 1,500 ml
HIP (high inspiratory pressure alarm)
  • 5 - 50 cm H?O
LIP (low inspiratory pressure alarm)
  • OFF, 1 - 40 cm H?O
Lo VE (low minute ventilation alarm)
  • OFF, 0.1 - 991 /min
LIP T (low inspiratory pressure delay time)
  • 5 - 60 sec

Need Quotation